Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Dermatol Surg ; 50(1): 62-68, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37815475

ABSTRACT

BACKGROUND: Needle-free hyaluronic acid (HA) jet injectors are gaining popularity for rejuvenation treatment. The devices are widely available online and are used for self-injection or in beauty salons by nonphysicians. However, little is known about their performance and safety. OBJECTIVE: To explore the injection efficiency and cutaneous biodistribution patterns administered with home-use compared with medical jet injectors and to assess safety aspects. MATERIALS AND METHODS: The authors injected HA into ex vivo human skin with 4 home-use and 2 medical injectors. The intracutaneous dose of HA was calculated, and the cutaneous biodistribution of HA was assessed using a 3-dimensional Fluorescent Imaging Cryomicrotome System (3D-FICS). Safety aspects were evaluated based on the presence of a manual, CE (conformité européenne) mark, and sterility. RESULTS: The intracutaneous dose delivered by the home-use injectors was markedly lower compared with the medical injectors. 3D imaging for home-use injectors showed superficial epidermal distribution with low distribution volumes. For medical injectors, volumes were substantially larger and mainly middermal. All evaluated safety aspects were lacking. CONCLUSION: Results of this study suggest that the specific combinations of home-use injectors and HA used in this study are unreliable and unsafe, which casts doubts on the performance of these treatments in general.


Subject(s)
Hyaluronic Acid , Skin , Humans , Hyaluronic Acid/adverse effects , Hyaluronic Acid/metabolism , Injections, Jet/methods , Tissue Distribution , Skin/metabolism , Administration, Cutaneous
2.
Sensors (Basel) ; 23(13)2023 Jul 04.
Article in English | MEDLINE | ID: mdl-37447996

ABSTRACT

The age estimation of biological traces is one of the holy grails in forensic investigations. We developed a method for the age estimation of semen stains using fluorescence spectroscopy in conjunction with a stoichiometric ageing model. The model describes the degradation and generation rate of proteins and fluorescent oxidation products (FOX) over time. The previously used fluorimeter is a large benchtop device and requires system optimization for forensic applications. In situ applications have the advantage that measurements can be performed directly at the crime scene, without additional sampling or storage steps. Therefore, a portable fiber-based fluorimeter was developed, consisting of two optimized light-emitting diodes (LEDs) and two spectrometers to allow the fluorescence protein and FOX measurements. The handheld fiber can be used without touching the traces, avoiding the destruction or contamination of the trace. In this study, we have measured the ageing kinetics of semen stains over time using both our portable fluorimeter and a laboratory benchtop fluorimeter and compared their accuracies for the age estimation of semen stains. Successful age estimation was possible up to 11 days, with a mean absolute error of 1.0 days and 0.9 days for the portable and the benchtop fluorimeters, respectively. These results demonstrate the potential of using the portable fluorimeter for in situ applications.


Subject(s)
Body Fluids , Semen , Semen/chemistry , Spectrometry, Fluorescence , Coloring Agents , Forensic Medicine/methods , Proteins/analysis
3.
Eur J Surg Oncol ; 47(5): 1034-1041, 2021 05.
Article in English | MEDLINE | ID: mdl-33077296

ABSTRACT

BACKGROUND: Anastomotic leakage is one of the most severe complications in patients undergoing esophagectomy with gastric tube reconstruction. Transection of the left gastric and gastro-epiploic artery and vein results in compromised perfusion which is seen as the major contributing factor for anastomotic dehiscence. The main objective of this prospective, observational, in-vivo pilot study is to microscopically evaluate gastric tube perfusion with Sidestream Darkfield Microscopy (SDF). METHODS: Intra-operative microscopic images of gastric-microcirculation were obtained with SDF directly after reconstruction in 22 patients. Quantitative perfusion related parameters were: velocity, Microvascular Flow Index(MFI), Total Vessel Density(TVD), Perfusion Vessel Density(PVD), Proportion of Perfused Vessels(PPV) and De Backer Score(DBS). Dedicated software was used to assess parameters predictive for compromised perfusion. RESULTS: SDF was feasible to accurately visualize and evaluate microcirculation in all patients. Velocity(µm/sec) was significantly decreased towards the fundus (p = 0.001). MFI, PVD and PVD were decreased distal of the watershed - between the right and left gastro-epiploic artery and vein - and in the fundus, compared to the base of the gastric tube(p = 0.0002). No differences in TVD and DBS were observed; because of vessel-dilation in the fundus-area. This suggests that venous congestion results in comprised inflow of oxygen rich blood and plays a role in the development of ischaemia. CONCLUSION: We present quantitative perfusion imaging with SDF of the gastric tube. Velocity, MFI, TVD and PPV are accurate parameters to observe perfusion decrease. Also, venous congestion is visible in the fundus, suggesting an important role in the development of ischaemia. These parameters could allow early risk stratification, and, potentially, can accomplish a reduction in anastomotic leakage.


Subject(s)
Esophagectomy/adverse effects , Microscopy/methods , Perfusion Imaging/methods , Plastic Surgery Procedures/methods , Stomach/blood supply , Adult , Aged , Anastomotic Leak/etiology , Female , Humans , Male , Microcirculation , Middle Aged , Pilot Projects , Prospective Studies
4.
Cytometry A ; 97(6): 582-591, 2020 06.
Article in English | MEDLINE | ID: mdl-32017331

ABSTRACT

Extracellular vesicles (EVs) are commonly studied by flow cytometry. Due to their small size and low refractive index, the scatter intensity of most EVs is below the detection limit of common flow cytometers. Here, we aim to improve forward scatter (FSC) and side scatter (SSC) sensitivity of a common flow cytometer to detect single 100 nm EVs. The effects of the optical and fluidics configuration on scatter sensitivity of a FACSCanto (Becton Dickinson) were evaluated by the separation index (SI) and robust coefficient of variation (rCV) of polystyrene beads (BioCytex). Improvement is defined as increased SI and/or reduced rCV. Changing the obscuration bar improved the rCV 1.9-fold for FSC. A 10-fold increase in laser power improved the SI 19-fold for FSC and 4.4-fold for SSC, whereas the rCV worsened 0.8-fold and improved 1.5-fold, respectively. Confocalization worsened the SI 1.2-fold for FSC, and improved the SI 5.1-fold for SSC, while the rCV improved 1.1-fold and worsened 1.5-fold, respectively. Replacing the FSC photodiode with a photomultiplier tube improved the SI 66-fold and rCV 4.2-fold. A 2-fold reduction in sample stream width improved both SI and rCV for FSC by 1.8-fold, and for SSC by 1.3- and 2.2-fold, respectively. Decreasing the sample flow velocity worsened rCVs. Decreasing the flow channel dimensions and the pore size of the sheath filter did not substantially change the SI or rCV. Using the optimal optical configuration and fluidics settings, the SI improved 3.8∙104 -fold on FSC and 30-fold on SSC, resulting in estimated detection limits for EVs (assuming a refractive index of 1.40) of 246 and 91 nm on FSC and SSC, respectively. Although a 50-fold improvement on FSC is still necessary, these adaptions have produced an operator-friendly, high-throughput flow cytometer with a high sensitivity on both SSC and FSC. © 2020 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.


Subject(s)
Extracellular Vesicles , Flow Cytometry , Light , Polystyrenes
5.
JMIR Res Protoc ; 9(1): e15687, 2020 Jan 21.
Article in English | MEDLINE | ID: mdl-31961326

ABSTRACT

BACKGROUND: Standard surgical treatments for lower urinary tract symptoms (LUTS) due to benign prostatic obstruction (BPO) use a transurethral approach. Drawbacks are the need for general or spinal anesthesia and complications such as hematuria, strictures, and cloth retention. Therefore, a minimal invasive technique under local anesthesia is desired to improve patient safety. Recently, SoracteLite transperineal laser ablation (TPLA) has been introduced as a novel minimal invasive treatment for BPO. The system used is unique because 4 laser sources are independently available. This 1064-nm diode laser induces coagulative necrosis. Moreover, TPLA is unique because it has a transperineal approach and can be performed under local anesthesia in an outpatient setting. OBJECTIVE: The primary objective of this study is to determine the safety and feasibility of TPLA treatment for men, who are fit for standard surgery, with LUTS due to BPO. The secondary objectives are to determine functional outcomes by flowmetry and patient-reported outcome measures (PROMs), side effects, and tissue changes observed on imaging. METHODS: This study is a prospective, single center, interventional pilot study IDEAL framework stage 2a and will include 20 patients. Eligible patients are men ≥40 years of age, with a prostate volume of 30 to 120 cc, have urodynamically proven bladder outlet obstruction, and have a peak urinary flow of 5 to 15 mL per second. All patients will undergo TPLA of their prostate under local anesthesia by using the EchoLaser system. Depending on the prostate volume, 2 to 4 laser fibers will be placed bilaterally into the prostate. Patient follow-up consists of uroflowmetry, PROMs, and imaging by using contrast-enhanced ultrasound. Total follow-up is 12 months following treatment. RESULTS: Presently, recruitment of patients is ongoing. Publication of first results is expected by early 2020. CONCLUSIONS: TPLA offers the potential to be a novel minimal invasive technique for treatment of LUTS due to BPO in men fit for standard desobstruction. This study will evaluate the safety and feasibility of TPLA and report on functional outcomes and tissue changes observed on imaging following TPLA treatment. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/15687.

6.
Dermatol Surg ; 46(4): 491-498, 2020 04.
Article in English | MEDLINE | ID: mdl-31574025

ABSTRACT

BACKGROUND: Bleomycin sclerotherapy is ineffective for treating capillary malformations (CMs) because bleomycin cannot adequately be injected into the small-diameter capillary lumina. Electrosclerotherapy (EST) might be a new treatment modality for CMs, as it combines bleomycin sclerotherapy and "electroporation"-an electric field applied to the tissue. Electroporation disrupts the transmembrane potential, facilitating bleomycin transportation across the vessel wall, hypothetically leading to targeted drug delivery and increased effectiveness of bleomycin in CMs. OBJECTIVE: To explore the efficacy, safety, and feasibility of EST for CMs in a randomized within-patient controlled pilot study. MATERIALS AND METHODS: Fifteen regions of interest (ROI) within the hypertrophic CMs of 5 patients were randomly allocated to EST, bleomycin injection, or no treatment. Outcome was assessed after 7 weeks by the patient and a blinded outcome assessor using the patient-observer scar assessment score (POSAS), global assessment of change (GAC), colorimetry, and laser speckle contrast imaging. RESULTS: Color and hypertrophy of all ROIs treated with EST significantly improved, based on the POSAS (medians patient -11; observer -13), GAC, and colorimetry (ΔE 3.4-16.5) scores. CONCLUSION: This pilot study demonstrates the first proof of concept for electrosclerotherapy as a new treatment modality for CMs. Further research is warranted.


Subject(s)
Bleomycin/administration & dosage , Capillaries/abnormalities , Electrochemotherapy/methods , Sclerotherapy/methods , Vascular Malformations/therapy , Adult , Aged , Bleomycin/adverse effects , Combined Modality Therapy/adverse effects , Combined Modality Therapy/methods , Electrochemotherapy/adverse effects , Feasibility Studies , Female , Humans , Injections, Intralesional , Male , Middle Aged , Patient Reported Outcome Measures , Pilot Projects , Sclerotherapy/adverse effects
7.
J Biophotonics ; 12(10): e201900037, 2019 10.
Article in English | MEDLINE | ID: mdl-31245913

ABSTRACT

This study investigates the feasibility of in vivo quantitative optical coherence tomography (OCT) of human brain tissue during glioma resection surgery in six patients. High-resolution detection of glioma tissue may allow precise and thorough tumor resection while preserving functional brain areas, and improving overall survival. In this study, in vivo 3D OCT datasets were collected during standard surgical procedure, before and after partial resection of the tumor, both from glioma tissue and normal parenchyma. Subsequently, the attenuation coefficient was extracted from the OCT datasets using an automated and validated algorithm. The cortical measurements yield a mean attenuation coefficient of 3.8 ± 1.2 mm-1 for normal brain tissue and 3.6 ± 1.1 mm-1 for glioma tissue. The subcortical measurements yield a mean attenuation coefficient of 5.7 ± 2.1 and 4.5 ± 1.6 mm-1 for, respectively, normal brain tissue and glioma. Although the results are inconclusive with respect to trends in attenuation coefficient between normal and glioma tissue due to the small sample size, the results are in the range of previously reported values. Therefore, we conclude that the proposed method for quantitative in vivo OCT of human brain tissue is feasible during glioma resection surgery.


Subject(s)
Brain Neoplasms/surgery , Brain/diagnostic imaging , Brain/surgery , Glioma/surgery , Intraoperative Period , Tomography, Optical Coherence , Brain Neoplasms/diagnostic imaging , Feasibility Studies , Glioma/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Pilot Projects , Software
8.
Lasers Surg Med ; 50(10): 980-986, 2018 12.
Article in English | MEDLINE | ID: mdl-29882233

ABSTRACT

BACKGROUND AND OBJECTIVES: A 36-year-old woman underwent CO2 laser resurfacing for periocular rhytides using protective stainless steel Cox II ocular shields. Immediately after the treatment, corneal lesions were seen in both eyes. The left eye subsequent developed corneal ulceration and scarring, a deformed iris, cataract, and lower eye lashes showing signs of acute burns. The right cornea had a small inferior mid-peripheral superficial lesion and concomitant lower mid-peripheral burned eye lashes. Our objective was to determine the most likely cause of these ocular complications. STUDY: We estimated temperature-time combinations that could induce corneal injury and cataract. Heat conduction effects from a heated cornea to the lens and from a heated ring of periocular skin to the cornea were computed. The temperature response of a shield following CO2 laser irradiation was determined. RESULTS: We computed that cataract can develop when the corneal temperature reaches, for example, 80 °C for 14 seconds. A periocular ring of heated skin contributes little to the corneal temperature. After 7 pulses of consecutive CO2 laser bursts in 7.5 seconds, the total shield area already reached a homogeneous temperature of 63 °C. CONCLUSION: Despite uncertainties in procedural details and modeling of cataract temperatures, the eye injuries were caused beyond doubt by heating of tear-covered metal eye shields by at least 10 consecutive but unintentional laser impacts. Lasers Surg. Med. 50:980-986, 2018. © 2018 Wiley Periodicals, Inc.


Subject(s)
Cataract/etiology , Corneal Injuries/etiology , Eye Protective Devices/adverse effects , Laser Therapy/adverse effects , Lasers, Gas , Rhytidoplasty/adverse effects , Adult , Carbon Dioxide , Female , Hot Temperature , Humans , Stainless Steel
9.
Sensors (Basel) ; 18(5)2018 Apr 25.
Article in English | MEDLINE | ID: mdl-29693606

ABSTRACT

In this study; an OCT-based intra-operative imaging method for blood flow detection during esophagectomy with gastric tube reconstruction is investigated. Change in perfusion of the gastric tube tissue can lead to ischemia; with a high morbidity and mortality as a result. Anastomotic leakage (incidence 5⁻20%) is one of the most severe complications after esophagectomy with gastric tube reconstruction. Optical imaging techniques provide for minimal-invasive and real-time visualization tools that can be used in intraoperative settings. By implementing an optical technique for blood flow detection during surgery; perfusion can be imaged and quantified and; if needed; perfusion can be improved by either a surgical intervention or the administration of medication. The feasibility of imaging gastric microcirculation in vivo using optical coherence tomography (OCT) during surgery of patients with esophageal cancer by visualizing blood flow based on the speckle contrast from M-mode OCT images is studied. The percentage of pixels exhibiting a speckle contrast value indicative of flow was quantified to serve as an objective parameter to assess blood flow at 4 locations on the reconstructed gastric tube. Here; it was shown that OCT can be used for direct blood flow imaging during surgery and may therefore aid in improving surgical outcomes for patients.


Subject(s)
Tomography, Optical Coherence , Esophageal Neoplasms , Esophagectomy , Humans , Microcirculation , Stomach
10.
Biomed Opt Express ; 9(9): 4196-4216, 2018 Sep 01.
Article in English | MEDLINE | ID: mdl-30615728

ABSTRACT

Treatment of resectable esophageal cancer includes neoadjuvant chemo-radiation therapy (nCRT) followed by esophagectomy in operable patients. High-risk surgery may have been avoided in patients with a pathological complete response (pCR). We investigated the feasibility of optical coherence tomography (OCT) to detect residual cancer and radiation-induced fibrosis in 10 esophageal cancer patients that underwent nCRT followed by esophagectomy. We compared our OCT findings with histopathology. Overall, OCT was able to differentiate between healthy tissue, fibrotic tissue, and residual cancer with a sensitivity and specificity of 79% and 67%, respectively. Hence, OCT has the potential to add to the assessment of a pCR.

SELECTION OF CITATIONS
SEARCH DETAIL
...